Caiki L.V
Expand/Contract AC contactor Series
Expand/Contract SM8 Series Moulded Case Circuit Breaker
Expand/Contract Box Series
Expand/Contract Mini Circuit Breaker Series
Range:
Keyword:
 
Any question?
Enquiry Now
Go Back | Print | Published time: 2006/06/07 00:59
RM-1 - CAIKI L.V Page Up | Page Down
  Name: RM-1
  Module: RM-1
  Attach 1 : Download
  Attach 2 : Download

product Standard : according to IEC60947£­2 and GB14048.2Standard ,
rated insulated voltage : 800V,
Frame Grade Rated Current : 63A, 100A, 225A, 400A, 630A, 800A, 1250A,
product Pole No. : 2 poles, 3 poles, 4 poles ,
breaking capability : Type L(Standard), Type M (a little high), Type H(High-breaking).
product outline : small, light, beautiful,
installation manner : upright installation and level installation,
connection manner : front connection, back connection, insert type ,
inside accessories : The minute urgestripping mechanism, lack voltage tripping mechanism, auxiliary contactor, alarm contactor ,
exterior accessories : electromotor operation wheel , turn handle operation wheel , machanical interlock wheel.

 Scope of application

         RM1 Series moulded case circuit breaker(hereinafter referred to as RM1) is one of our company new type circuit breakers which is adopted international advanced design and manufacture technic to develop by ourselves. And its rated insulated voltage is 800V(RM1£­63is 500V), applied to AC 50HZ(60Hz), rated voltage 690V(RM1£­63is 400V), direct current 250V or less, rated working current 10A up to 1250A. it used in switching the circuitry and starting electromotor unfrequent. RM1 have overload, short-circuit and lack voltage protection, protecting circuitry and power equipment without damage.
        RM1 according to rated limit short-circuit breaking capability (Icu): Type L (standard), Type M (High-breaking Type), Hstyle (High-breaking Type). They have many characteristic of reasonable structure, small volume, high breaking capability, short fly arc distance (parts of specification no fly arc), vibration resist etc. It¡¯s suitable in ship or land.
         This circuit breaker can be upright installation and level installation.
         This circuit breaker product accord to Standard as follows :
         IEC947-1and GB14048.1general rules
         IEC947-2and GB14048.2low voltage Circuit Breaker
         IEC947-4and GB14048.4contactor and electromotor starter 
         IEC947-5.1and GB14048.5 mechanical control circuit electric 

Installation Location Altitude Is Under 2000m;
Ambient Medium Temperature Between +40¡æ(Ship Use Product Is +45¡æ) And -5¡æ;
Endure Infection Of Moist Air;
Endure Infection Of Salt Fog And Oil Fog;
Endure Infection Of Mildew;
Endure Infection Of Nucleus Radiate;
Max Gradient Is ¡À22.5¡ã;
Working Reliably Under Ship Normally Vibration;
Working Reliably Under Earthquake(4g);
The Place With Medium Of No Blast Danger And Not Canker The Metal And Damage Insulated Air And  Electric Dust;
The Place Without Attack Of Rain And Snow.

Remark : 1)Distribution Use Circuit Breaker No Code ,protection Electromotor Use Circuit BreakerÒÔ2means .
              2)Direct Operation No Code ,electromotor Operation Use Pmeans ,turn Handle Operation ÒÔzmeans .
According To Product Pole No. : 2 Poles (100, 225), 3 Poles And 4 Poles (No Rm1-1250). In 4 Poles Product N Pole Include :
            Type A : N Pole Not Installation Over Current Tripping Component , And N Pole Always Turn-on, Not Close And Open Together With Other 3 Poles ,
            Type B : N Pole Not Installation Over Current Tripping Component , And N Pole Close And Open Together With Other 3 Poles,(N Pole First Close And Then Open)
            Type C : N Pole Installation Over Current Tripping Component , And N Pole Close And Open Together With Other 3 Poles ,(N Pole First Close And Then Open)
            Type D : N Pole Installation Over Current Tripping Component , And N Pole Always Turn-on, Not Close And Open Together With Other 3 Poles.
According To Rated Current (A): Rm1-63is (6), 10, 16, 20, 25, 32, 40, 50, 63a¾Ålevel ,(6aspecification None Overload Protection )
            Rm1-100is (10), 16, 20, 25, 32, 40, 50, 63, 80, 100a
            Rm1-225is 100, 125, 140, 160, 180, 200, 225a,
            Rm1-400is 225, 250, 315, 350, 400a
            Rm1-630is 400, 500, 630a
            Rm1-800is 630, 700, 800a
            Rm1-1250is 800, 1000, 1250a£ÛWith ()is Not Groom Specification £Ý,
According To Connection Manner : Front Connection, Back Connection, Insert Type
According To Over Current Tripping Mechanism Type: Thermal-electromagnetic (Duplicate)style, Electromagnetic (Instantaneous )style .
According To Accessorial Set: With Accessorial Set And Without Accessorial Set :
           Accessorial Set Include Inside Equipment And Exterior Equipment ,
           Inside Equipment With The Minute Urgestripping Mechanism, Lack Voltage Tripping Mechanism, Auxiliary Contactor, Alarm Contactor,
           Exterior Equipment With The Turn Handle Operation Wheel , Electromotor Operation Wheel , Interlock Wheel And Connection Terminal Of Auxiliary Equipment Etc.



 

 

Go Back | Go Top | Print